800w High Frequency Pulse Electroplating Power Supply
high frequency pulse electroplating power supply
Features: · High reliability, low ripple · AC input range selected by switch · Protections: Short circuit/ Over load/ Over voltage/ Over temperature · Built-in remote ON-OFF control and remote sense function · With parallel function · Can adjust from 20%~100% output voltage by external control 1-5V · Forced air cooling by built-in DC fan · 1 year warranty · Dimensions: 291*132*68mm(L*W*H) |
MODEL | SCN-800-12 | SCN-800-15 | SCN-800-24 | SCN-800-48 |
OUTPUT | DC Voltage | 12V | 15V | 24V | 48V |
Voltage Tolerance | ±1% | ±1% | ±1% | ±1% |
Rated Current | 66A | 54A | 33A | 16.6A |
Current Range | 0-66A | 0-54A | 0-33A | 0-16.6A |
Rated Power | 800W | 800W | 800W | 800W |
Ripple & Noise | 150mVp-p | 150mVp-p | 240mVp-p | 480mVp-p |
DC Adjustment Range | ±5%; Can adjust from 40%~100% output voltage by external control 2-5V |
Setup, Rise, Hold Time | 800ms, 50ms, 16ms at full load |
INPUT | Voltage Range | 90~130VAC / 180~260 VAC47~63 Hz;selected by switch260~370VDC |
AC Current | 18A/115 VAC 9A/ 230 VAC |
Efficiency | 80% | 81% | 85% | 87% |
Inrush Current | 60A/230V |
Leakage Current | <3.5mA/240VAC |
PROTECTION | Over Load | 110%~135% |
Protection: Protection:Current limiting, delay shut down o/p voltage, re-power on to recover |
Over Voltage | 110%~135% |
Protection type: Shut down o/p voltage, re-power on to recover |
Over Temp | TSW1(Power transistor) When temp. >100 °C, shut down o/p voltage, re-power on to recover |
ENVIRONMENT | Working Temp., Humidity | -10°C~+60°C,20%~90 %RH |
Storage Temp., Humidity | -20°C~+85°C,10%~95 %RH |
Vibration | 10~200Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
SAFETY | Withstand Voltage | I/P-O/P, I/P-FG:1500VAC |
Isolation Resistance | I/P-O/P, I/P-FG, >100M Ohms / 500VDC |
STANDARD | Safety Standard | Design refer to UL1950,CSA22.2,IEC60950 |
EMC Standard | Design refer to FCC Part 15 Class A |
OTHERS | Dimension | 291*132*68mm(L*W*H) |
Weight | 2.3Kg |
Packing | 8pcs/24.0kg/CARTON |
NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
Continuously improve CQTS to satisfy customer is our goal !